CRT TUBE PHILIPS A59-23W
59cm (23in) direct viewing television tube with metal backed screen and reinforced envelope. A separate safety screen is not required. This tube is electrically identical to the A59-11W. Suitable for use in receivers with push-through presentation.
Deflection 110° deg
Focusing Electrostatic
Light transmission (approx.) 50 %
Maximum overall length 36.7 cm.
FOCUSING Electrostatic
The range of focus voltages shown in 'OPERATING CONDITIONS' results
in optimum overall focus at a beam current of 250nA.
DEFLECTION Magnetic
EXTERNAL CONDUCTIVE COATING
This tube has an external conductive coating, M, which must be connected to chassis, and the capacitance of this coating to the final anode is used to provide smoothing for the e.h.t. supply. The electrical connection to this coating must be made within the area specified on the tube outline drawing.
MOUNTING POSITION
Any. The tube socket should not be rigidly mounted but should have flexible leads and be allowed to move freely. The bottom circumference of the base shell will fall within a circle of 40mm diameter which is centred upon the perpendicular from the centre of the face. This tube is fitted with a pin protector in order to avoid damage to the glass base due to bending of the base pins whilst handling the tube. It is advisable to keep this pin protector on the base until it can be replaced by the socket after installation of the tube in any equipment.
NOTES
1. Adequate precautions should be taken to ensure that the receiver is protected from damage which may be caused by a possible high voltage flashover within the cathode ray tube.
2. Maximum pulse duration 22% of one cycle with a maximum of 1,5ms.
3. The d.c. value of bias must not be such as to allow the grid to become positive with respect to the cathode, except during the period immediately after switching the receiver on or off when it may be allowed to rise to +2V, It is advisable to limit the positive excursion of the video signal to +5V (pk) max, This may be achieved automatically by the series connection of a 10k resistor.
4. During an equipment warm-up period not exceeding 15 seconds Vp 4 (pk) max, (cathode positive) is allowed to rise to 410V. Between 15 and 4 seconds after switching on, a decrease in vp 4 (px) max. (cathode positive) proportional with time from 410V to 250V is permissible.
The metal band (B) should be connected directly to the chassis in an a.c. receiver operating from an isolating transformer, or via a suitable leakage path in an a.c./d.c. receiver. The mounting lugs will be in electrical contact with the metal band.
WARNING
X-ray shielding is advisable to give protection against possible danger of personal injury arising from prolonged exposure at close range to this tube when operated above 20kV.












No comments:
Post a Comment
The most important thing to remember about the Comment Rules is this:
The determination of whether any comment is in compliance is at the sole discretion of this blog’s owner.
Comments on this blog may be blocked or deleted at any time.
Fair people are getting fair reply. Spam and useless crap and filthy comments / scrapers / observations goes all directly to My Private HELL without even appearing in public !!!
The fact that a comment is permitted in no way constitutes an endorsement of any view expressed, fact alleged, or link provided in that comment by the administrator of this site.
This means that there may be a delay between the submission and the eventual appearance of your comment.
Requiring blog comments to obey well-defined rules does not infringe on the free speech of commenters.
Resisting the tide of post-modernity may be difficult, but I will attempt it anyway.
Your choice.........Live or DIE.
That indeed is where your liberty lies.
Note: Only a member of this blog may post a comment.