CRT TUBE PHILIPS A37-590X/0620
Hi-Bri COLOUR PICTURE TUBE
@ 90° deflection
@ In-line gun, thermally stable; electrostatic hi-bi potential focus
@ 29,1 mm neck diameter
© Hi-Bri screen with pigmented phosphor featuring high brightness and increased contrast performance
@ Soft-Flash technology offering improved set reliability
@ Slotted shadow mask optimized for minimum moiré
@ Fine pitch over entire screen
@ Phosphor lines follow glass contour
@ Quick-heating cathodes
@ Internal magnetic shield
@ Reinforced envelope for push-through mounting
@ Anti-crackle coating
@ When combined with an appropriate hybrid saddle toroidal deflection unit (e.g. AT1206), it forms a
self-converging and raster correction free assembly.
Notes to outline drawings
1. Configuration of outer conductive coating may be different, but will contain the contact area as shown in the drawing.
2. To clean this area, wipe only with a soft lintless cloth.
3.
One of the four mounting lugs may deviate (1,5 mm max.) from the plane
of the other three lugs. This deviation is incorporated in the tolerance
of + 1,8 mm.
4. Minimum space to be reserved for mounting lug.
5. The position of the mounting screw in the cabinet must be within a circle of 7,5 mm diameter drawn
around the true geometrical positions, i.e. the corners of a rectangle of 311,4 mm x 243,2 mm.
6. Co-ordinates for radius R = 11,6 mm: x = 126,98 mm, y = 90,76 mm.
7. Not applicable.
8.
The socket for this base should not be rigidly mounted; it should have
flexible leads and be allowed to move freely. After mounting of the tube
in the cabinet note that the position of the base can fall within a
circle, having a diameter of max. 50 mm, concentric with an imaginary
tube axis. The mass of the mating socket with circuitry should not be
more than 150 g, maximum permissible torque is 40 mNm.
9. Small cavity contact J1-21, 1EC67-III-2.
10.
The X, Y and Z reference points are located on the outside surface of
the face plate at the intersection of the minor, major and diagonal
screen axis respectively, with the minimum published screen.
Notes to the limiting values
1. Absolute maximum rating system.
2. The picture tube does not emit X-radiation above 1 uSv/h when operated within its absolute
maximum ratings.
3.
During adjustment on the production line this value is likely to be
surpassed considerably. It is therefore strongly recommended to first
make the necessary adjustments for normal operation without picture
tube.
4. Operation of the tube at lower voltages impairs the luminance and resolution.
5. The short-term average anode current should be limited by circuitry to 1000 pA.
6.
For maximum cathode life and optimum performance, it is recommended
that the heater supply be designed for 6,3 V at zero beam current.
FLASHOVER PROTECTION
With
the high voltage used with this tube (max. 27,5 kV) internal flashovers
may occur. As a.result of the Soft-Flash technology these flashover
currents are limited to approx. 60 A offering higher set reliability,
optimum circuit protection and component savings. Primary protective
circuitry using properly grounded spark gaps and series isolation
resistors (preferably carbon composition) is still necessary to prevent
tube damage. The spark gaps should be connected to all picture tube
electrodes at the socket according to the figure below; they are not
required.on the heater pins. No other connections between the outer
conductive coating and the chassis are permissible. The spark gaps
should be designed for a breakdown voltage at the focusing electrode
(g3) of 11 kV (1,5 x Vg3 max. at Va gq = 25 kV), and at the other
electrodes of 1,5 to 2 kV. The values of the series isolation resistors
should be as high as possible (min. 1,5 k&) without causing
deterioration of the circuit performance. The resistors should be able
to withstand an instantaneous surge of 20 kV for the focusing circuit
and 12 kV for the remaining circuits without arcing.
DEGAUSSING
The
picture tube is provided with an internal magnetic shield. This shield
and the shadow mask with its suspension system may be provided with an
automatic degaussing system, consisting of one magnetic coil winding
mounted on the cone of the picture tube.
Symbols denoting electrodes/elements and electrode/element connections
f Heater
k Cathode
g Grid: Grids are distinguished by means of an additional numeral:
the electrode nearest to the cathode having the lowest number.
a Anode
m External conductive coating
m’ Rimband
Q Fluorescent screen
ic. Tube pin which must not be connected externally
nc Tube pin which may be connected externally
Symbols denoting voltages
Unless otherwise stated, the reference point for electrode voltages is the cathode.
Vv Symbol for voltage, followed by a subscript denoting the relevant electrode/element
Ve Heater voltage
Vp-p Peak-to-peak value of a voltage
Vp Peak value of a voltage
VGR Grid 1 voltage for visual extinction of focused raster (grid drive service)
VKR Cathode voltage for visual extinction of focused raster (cathode drive service)
GENERAL OPERATIONAL RECOMMENDATIONS INTRODUCTION
Equipment
design should be based on the characteristics as stated in the data
sheets. Where deviations from these general recommendations are
permissible or necessar y, statements to that effect will be made. If
applications are considered which are not referred to in the data sheets
of the relevant tube type, extra care should be taken with circuit
design to prevent the tube being overloaded due to unfavourable
operating conditions.
SPREAD IN TUBE CHARACTERISTICS
The
spread in tube characteristics is the difference between maximum and
minimum values. Values not as No qualified spread figures, as maximum is
given may for differ or minimum values according of characteristics are
to nominal the number ones. in settings of It is tubes evident
substantially of a that certain average differing type or that nominal
from are those being values, checked. specified as well guaranteein the
data sheets.
SPREAD AND VARIATION IN OPERATING CONDITIONS
The
operating conditions of a tube are subject to spread and/or variation.
Spread in an operating condition is a permanent deviation from an
average condition due to, e.g., component value deviations. The average
condition is found from such a number individual cases taken at random
that an increase of the number will have a negligibl e influence.
Variation in an operating condition is non-permanent (occurs as a
function of time), e.g., due to supply voltage fluctuations. The average
value is calculated over a period such that a prolongation of that
period will have negligible influence.
LIMITING VALUES
Limiting
values are in accordance with the applicable rating system as defined
by IEC Publication 134. Reference may be made to one of the following 3
rating systems. Absolute maximum rating system. Absolute maximum ratings
are limiting values of Operating and environmental conditions
applicable to any electronic device of a specified type as defined by
its published data, and should not be exceeded under the worst probable
conditions. These values are chosen by the device manufacturer to
provide acceptable serviceability of the device, taking no
responsibility for equipment variations, environmental variations, and
the effects of changes in operating conditions due to variations in the
characteristics of the device under consideration and of all other
electronic devices in the equipment. value The equipment for the
intended manufacturer service is should exceeded design with so that,
any device initially under and the throughout worst probable life, no
absolute operating maximum conditions with respect to supply voltage
variation, equipment compone nts spread and variation, equipment control
adjustment, load variations, signal variation, environ mental
conditions, and spread or variations in characteristics of the device
under considerations and of all other electronic devices in the
equipment.
Design-maximum rating system.
Design-maximum
ratings are limiting values of operating and environ- mental conditions
applicable to a bogey electronic device* of a specified type as defined
by its pub- lished data, and should not be exceeded under the worst
probable conditions.
These values are chosen by the device
manufacturer to provide acceptable serviceability of the device, taking
responsibility for the effects of changes in operating conditions due to
variations in the characteristics of the electronic device under
consideration.
The equipment manufacturer should design so that,
initially and thoughout life, no design-maximum value for the intended
service is exceeded with a bogey device under the worst probable
operating conditions with respect to supply-voltage variation, equipment
component variation, variation in char- acteristics of all other
devices in the equipment, equipment control adjustment, load variation,
signal variation and environmental conditions.
Design-centre
rating system. Design-centre ratings are limiting values of operating
and environmental conditions applicable to a bogey electronic device* of
a specified type as defined by its published data, and should not be
exceeded under average conditions. These values are chosen by the device
manufacturer to provide acceptable serviceability of the device in
average applications, taking responsibility for normal changes in
operating conditions due to rated supply-voltage variation, equipment
component spread and variation, equipment control adjustment, load
variation, signal variation, environmental conditions, and variations or
spread in the characteristics of all electronic devices. The equipment
manufacturer should design so that, initially, no design-centre value
for the intended service is exceeded with a bogey electronic device* in
equipment operating at the stated normal supply voltage. If the tube
data specify limiting values according to more than one rating system
the circuit has to be designed so that none of these limiting values is
exceeded under the relevant conditions. The expressions ‘long-term’ and
‘short-term’ are used to denote either the maximum time-averaged beam
current for one gun to limit the cathode loading, or the maximum
time-averaged anode current for three guns to limit the screen loading.
‘Short-term’ is not related to a specific period of time, but can be
interpreted as the condition where the content and intensity of the
displayed image vary continuously, as during live television pictures.
‘Long-term’ means that the image is stationary for an indefinite period
of time, as during the display of test pictures, computer images,
teletext data or stationary television scenes lasting longer than 30
seconds. In addition to the limiting values given in the individual data
sheets the directives in the following paragraphs should be observed.
HEATER SUPPLY
For
maximum cathode life and optimum performance it is recommended that the
heater supply be designed at the nominal heater voltage at zero beam
current. Any deviation from this heater voltage has a detrimental effect
on tube performance and life, and should therefore be kept to a
minimum. In any case the deviations of the heater voltage must not
exceed + 5% and —10% from the nominal value at zero. beam current.
Such deviations may be caused by:
@ mains voltage fluctuations;
® spread in the characteristics of components such as transformers, resistors, capacitors, etc.;
® spread in circuit adjustments;
® operational variations.
CATHODE TO HEATER VOLTAGE
The
voltage between cathode and heater should be as low as possible and
never exceed the limiting values given in the data sheets of the
individual tubes. The limiting values relate to that side of the heater
where the voltage between cathode and heater is greatest. The voltage
between cathode and heater may be DC, AC or a combination of both.
Unless otherwise stated, the maximum values quoted indicate the maximum
permissible DC voltage. If a combination of DC and AC voltages is
applied, the peak value may be twice the rated Vkf; however, unless
otherwise stated, this peak value shall never exceed 315 V. Unless
otherwise stated, the Vk¢ max. holds for both polarities of the voltage;
however, a positive cathode is usually the most favourable in view of
insulation during life. A DC connection should always be present between
heater and cathode. Unless otherwise specified the maximum resistance
should not exceed 1 MQ; the maximum impedance at mains frequency should
less than 100 kohm.
INTERMEDIATE ELECTRODES
(between cathode
and anode) in no circumstances should the tube be operated without a DC
connection between each electrode and the cathode. The total effective
impedance between each electrode and the cathode should never exceed the
published maximum value. However, no electrode should be connected
directly to a high energy source. When such a connection is required, it
should be made via a series resistor of not less than 1kohm.
CUT-OFF VOLTAGE
Curves
showing the limits of the cut-off voltage as a function of grid 2
voltage are generally. included in the data. The brightness control
should be so dimensioned that it can handle any tube within the limits
shown, at the appropriate grid 2 voltage. The published limits are
determined at an ambient illumination level of 10 lux. Because the
brightness of a spot is in general greater than that of a raster of the
same current, the cut-off voltage determined with the aid of a focused
spot will be more negative by about 5 V as compared with that of a
focused
raster.
TUBE OPERATING PRECAUTIONS
To prevent permanent screen damage, care should be taken:
— not to operate the tube with a stationary picture at high beam currents for extended periods;
— not to operate the tube with a stationary or slowly moving spot except at extremely low beam currents;
—
if no EHT bleeder is used, to choose the time constants of the cathode,
grid 1, grid 2, and deflection circuits, such that sufficient beam
current is maintained to discharge the EHT capacitance before deflection
has ceased after equipment has been switched off.
To prevent stray emissions:
— the anode voltage should be less than 12 kV within 5 seconds of switch-off. To prevent permanent damage to the screen:
—
it is strongly advised to provide the video drive circuitry with a
facility which blanks the tube automatically in the event of a
deflection failure. This is particularly important in applications where
the deflection coil is DC coupled to the vertical output stage, as a
short-circuit fault in this stage may otherwise lead to immediate
de-evacuation of the tube (pierced neck).
EXTERNAL CONDUCTIVE COATING
The
external conductive coating must be connected to the chassis. The
capacitance of this coating to the final accelerating electrode may be
used to provide smoothing for the EHT supply. The coating is not a
perfect conductor and in order to reduce electromagnetic radiation
caused by the line time base and the picture content it may be necessary
to make multiple connections to the coating. See also ‘Flashover’.
METAL RIMBAND
An
appreciable capacitance. exists between the metal rimband and the
internal conductive coating of the tube; its value is quoted in the
individual data sheets. To avoid electric shock, a DC connection should
be provided between the metal band and the external conductive coating.
In receivers where the chassis can be connected directly to the mains
there is a risk of electric shock if access is made to the metal band.
To reduce the shock to the safe limit, it is suggested that a 2 MQ
resistor capable of handling the peak voltages be inserted between the
metal band and the point of contact with the external conductive
coating. This safety arrangement will provide the necessary insulation
from the mains but in the event of flashover high voltages will be
induced on the metal band. It is therefore recommended that the 2 MQ
resistor be bypassed by a 4.7 nF capacitor capable of withstanding the
peak voltage determined by the voltage divider formed by this capacitor
and the capacitance of the metal rimband to the internal conductive
coating, and the anode voltage. The 4.7 nF capacitor also serves to
improve EHT smoothing by adding the rimband capacitance to the
capacitance of the outer conductive coating.
FLASHOVER
High
electric field strengths are present between the gun electrodes of
picture tubes. Voltages between gun electrodes may reach values of 20 kV
over approx. 1mm. Although the utmost precautions are taken in the
design and manufacture of the tubes, there is always a chance that
flashover will occur. The resulting transient currents and voltages may
be of sufficient magnitude to cause damage to the tube itself and to
various components on the chassis. Arcing terminates when the EHT
capacitor is discharged. Therefore it is of vital importance to provide
protective circuits with spark gaps and series resistors, which should
be connected according to Fig. 1. No other connections between the outer
conductive coating and the chassis are permissible. As our picture
tubes are manufactured in Soft-F lash technology, the peak discharge
currents are limited to approx. 60 A, offering higher set reliability,
optimum circuit protection and component savings (see also Technical
Note 039). However this limited value of 60 A is still too high for the
circuitry which is directly connected to the tube socket. Therefore
Soft-Flash picture tubes should also be provided with spark gaps.
IMPLOSION PROTECTION
All
picture tubes employ integral implosion protection and must be replaced
with a tube of the same type number or recommended replacement to
assure continued safety. HANDLING Although all picture tubes are
provided with integral implosion protection, which meets the intrinsic
protection requirements stipulated in the relevant part of IEC 65, care
should be taken not to scratch or knock any part of the tube. The tube
assembly should never be handled by the neck, deflection unit or other
neck components. A picture tube assembly can be lifted from the
edge-down position by using the two upper mounting lugs. An alternative
lifting method is firmly to press the hands against the vertical sides
of the rimband. When placing a tube assembly face downwards ensure that
the screen rests on a soft pad of suitable material, kept free from
abrasive substances. In all handling procedures prior to insertion in
the receiver cabinet there is a risk of personal injury as a result of
severe accidental damage to the tube. It is therefore recommended that
protective clothing should be worn, particularly eye shielding. When
suspending the tube assembly from the mounting lugs ensure that a
minimum of 2 are used; UNDER NO CIRCUMSTANCES HANG THE TUBE ASSEMBLY
FROM ONE LUG.
SOAK TESTING
To ensure that the operating
conditions of the tube are optimized for the long term, a short
stabilization period is required, afer which, the cut-off adjustment
should be made and the performance assessed. It is recommended that the
tube should be soak-tested for a minimum period of 2 hours running time,
before it is adjusted to its final operating conditions. After soak
testing, if the tube is switched off for a period of 90 seconds or more,
a reheat time of 15 minutes is required before making final cut-off
adjustments and picture assessment. Where the tube is switched off for
less than 90 seconds, the reheat time required is 10 times the
switched-off period. If provided the slots in the rimband of colour
picture tubes are used in the mounting of the degaussing Coils. It is
not recommended to suspend the tube assembly from one or more of these
slots as permanent deformation to the rimbnad can occur. Remember when
replacing or servicing the tube assembly that a residual electrical
charge may be carried by the anode contact and also the external coating
if not earthed. Before removing the tube assembly from the equipment,
earth the external coating and short the anode contact to the coating.
The tube should under no circumstances be subjected to accelerations
greater than 350 m/s?. Observe any instructions given on the packing and
handle accordingly.
MOUNTING
Unless otherwise specified on
the data sheets for individual tubes there are no restrictions on the
position of mounting. The tube socket should not be rigidly mounted but
should have flexible leads and be allowed to move freely.
DEGAUSSING
Colour
picture tubes employ internal magnetic shielding. However, for
individual tube types, optimal degaussing coils and circuitry are
advised. Strong magnetic fields possibly existing during transportation
of the tubes, and the manufacturing process of the television sets, may
induce magnetic remanence.-This remanence cannot always be removed by
the automatic degaussing circuitry of the set. It is therefore strongly
recommended to apply an external degaussing field of sufficient
magnitude and uniformity on the assembly line. This should be followed
by activation of the internal set degaussing, with the set positioned in
the same terrestrial orientation as for testing and performance
judgement.
LOCAL MAGNETIC FIELDS
Care should be taken to
avoid local AC or DC magnetic fields such as loudspeakers and
transformers. The influence to beam shift may not exceed 5 microns
anywhere on the screen surface.
No comments:
Post a Comment
The most important thing to remember about the Comment Rules is this:
The determination of whether any comment is in compliance is at the sole discretion of this blog’s owner.
Comments on this blog may be blocked or deleted at any time.
Fair people are getting fair reply. Spam and useless crap and filthy comments / scrapers / observations goes all directly to My Private HELL without even appearing in public !!!
The fact that a comment is permitted in no way constitutes an endorsement of any view expressed, fact alleged, or link provided in that comment by the administrator of this site.
This means that there may be a delay between the submission and the eventual appearance of your comment.
Requiring blog comments to obey well-defined rules does not infringe on the free speech of commenters.
Resisting the tide of post-modernity may be difficult, but I will attempt it anyway.
Your choice.........Live or DIE.
That indeed is where your liberty lies.
Note: Only a member of this blog may post a comment.